SOURCE RECORD / S0192

Leveraging textured flickers: a leap toward practical, visually comfortable, and high-performance dry EEG code-VEP BCI

Evidence A

Leveraging textured flickers: a leap toward practical, visually comfortable, and high-performance dry EEG code-VEP BCI

Authors or organization
Dehais F, Cabrera Castillos K, Ladouce S, Clisson P
Published date
2024-12-03
Source type
peer_reviewed_human_study
Technology route
non-invasive 8-dry-electrode code-VEP EEG
Function or setting
assistive communication and HCI
Rights status
metadata_only

Evidence summary

Evidence: Practical low-density dry EEG code-VEP feasibility. Key figures: 93.6% Gabor and 96.3% Ricker versus 65.6% plain with 88 s calibration; online 97.5% cued and 94.3% asynchronous; mean decoding time 1.68 s. Limitations: Healthy participants; five-class task; task-specific calibration and stimuli; abstract does not establish patient, home, long-term, or cross-device performance.

Key figures

93.6% Gabor and 96.3% Ricker versus 65.6% plain with 88 s calibration; online 97.5% cued and 94.3% asynchronous; mean decoding time 1.68 s

Limitations

Healthy participants; five-class task; task-specific calibration and stimuli; abstract does not establish patient, home, long-term, or cross-device performance