SOURCE RECORD / S0044
Stable decoding from a speech BCI enables control for an individual with ALS without recalibration for 3 months
Stable decoding from a speech BCI enables control for an individual with ALS without recalibration for 3 months
- Authors or organization
- not_public
- Published date
- 2023
- Source type
- peer_reviewed_human_study
- Technology route
- fully implanted ECoG CortiCom
- Function or setting
- assistive communication
- Rights status
- metadata_only
Legacy aliases
—
Related topics
- BCI 最优方案
Evidence summary
Evidence: Online self-paced speech-command control. Key figures: 6 commands; median accuracy 90.59%; no recalibration. Limitations: Single participant; same CortiCom cohort; command accuracy not spelling throughput.
Key figures
6 commands; median accuracy 90.59%; no recalibration
Limitations
Single participant; same CortiCom cohort; command accuracy not spelling throughput
This source currently has a local metadata record only. No public mirror is provided because redistribution permission has not been confirmed; use the original source above for verification.